Introduction
Partial upper sternotomies are described for a minimally invasive approach to valvular and ascending aortic surgery (1). Nowadays, MICS-AVR is growing to be performed by many surgeons (2). MICS-AVR did not increase morbidity or mortality; however, they may be reduced without compromising the excellent outcome. It reduced postoperative bleeding, the need for blood transfusions, the length of stay in the hospital, and sternal dehiscence (3).
Upper mini-sternotomy improves surgical outcome and reduces morbidity in AVR (4). Other authors enumerated disadvantages of the minimally invasive approach, like longer CPB and ACC times and an increased incidence of stroke due to retrograde perfusion through femoral cannulation (5).
Methods
In MICS-AVR, all surgical steps were similar to a standard full sternotomy except those steps. A roll is placed behind the right shoulder to elevate that side 30°–45°. External defibrillator pads are placed because we cannot use internal pads due to a small incision.
The sternum was incised down to the 4th space with preservation of the right internal thoracic artery (RITA) (Figure 1). A smaller sternal retractor is used. We began with central aortic and right atrial cannulation, then moved on to femoral cannulation via open cut-down or Seldinger technique. Transesophageal echocardiography (TOE) was used to evaluate cannulation, de-airing, and valve function after replacement.
Pacing wires are inserted during the arrest. Only four stainless steel wires are used to approximate the sternal halves.
Results
The study began in January 2019 and will conclude in December 2022, with 230 patients undergoing isolated AVR via a mini sternotomy. Postoperative results for early (3 months) and midterm (1 year) were followed up. Early mortality was 1% (2 patients) due to stoke postoperatively and prolonged mechanical ventilation.
The stroke was related to old age and a history of previous strokes. Also, there were 4% (4 patients) with different morbidities: (i) heart failure due to severe aortic insufficiency (AI); (ii) late mild ischemic stroke resolved without deficit; (iii) trivial paravalvular leak without hemolysis treated with follow-up; and (iv) injury of the right internal thoracic artery and ligation (with clip). The average age was 58 ± 9.7 years.
The average Euro-Score was 4.7% ± 3.2, with an EF of 40% ± 4.3. The mean ACC time for patients with MICS-AVR was 83 ± 17 min and the mean CPB time was 114 ± 34 min. The mean time of MV was 4.3 ± 2.5 h, the average time in the ICU was 1.3 ± 1.2 days, and the average stay in the hospital was 4.2 ± 1.3 days.
There was no case of bleeding and wound infection. No conversion to sternotomy was performed.
Discussion
The main drawback of the mini-sternotomy approach is the difficulty of de-airing (6). There was no problem during de-airing by CO2 insufflation, Trendelenburg position, aortic root, and TOE.
Mini-sternotomy AVR is a safe procedure with the same efficacy as a full sternotomy (4). As the number of patients increases, so does the learning curve and the efficacy of the technique.
In MICS-AVR, there is no risk of complete sternal dehiscence and an early return to work (7). As in our cases, there was no sternal rocking or infection.
MICS-assisted AVR has the same mortality and postoperative stroke as standard sternotomies (1). Also, in our cases, a minimal approach or access did not increase mortality.
A J-shaped mini-sternotomy or partial upper sternotomy is an approach that concerns decreasing surgical trauma, enhancing convalescence, and improving the cosmesis of the incision (8). Other investigators have not been able to show any advantage to MICS-AVR approaches except a smaller incision (3). Our research confirmed that this was not just a cosmetic approach, but that it was also safe and effective. It also improved the outcome.
Conclusion
MICS-AVR is a safe and effective procedure. It has the advantage of a small cosmetic incision, patient satisfaction, and an early return to normal activity without increasing morbidities or mortalities.
Limitations
This study is not a comparative cohort study, and there is no statistical analysis.
Author contributions
The author confirms being the sole contributor of this work and has approved it for publication.
Abbreviations
ACC, aortic cross clamp; AI, aortic insufficiency; ARE, aortic root enlargement; CPB, cardio pulmonary bypass; EF, ejection fraction; MICS-AVR, minimal invasive cardiac surgery aortic valve replacement; ICU, intensive care unit; TOE, trans esophageal echography; MV, mechanical ventilation; RITA, right internal thoracic artery.
References
1. Ghoreishi M, Thourani V, Badhwar V, Massad M, Svensson L, Taylor B, et al. Less-invasive aortic valve replacement: trends and outcomes from the society of thoracic surgeons database. Ann Thorac Surg. (2021) 111:1216–24.
2. Mikus E, Turci S, Calvi S, Ricci M, Dozza L, Del Giglio M. Aortic valve replacement through right minithoracotomy: is it really biologically minimally invasive? Ann Thorac Surg. (2015) 99:826–30.
3. Gilmanov D, Bevilacqua S, MurzIi M, Cerillo A, Gasbarri T, Enkel K, et al. Minimally invasive and conventional aortic valve replacement: a propensity score analysis. Ann Thorac Surg. (2013) 96:837–43.
4. Szwerc M, Benckart D, Wiechmann R, Savage E, Szydlowski G, Magovern G, et al. Partial versus full sternotomy for aortic valve replacement. Ann Thorac Surg. (1999) 68:2209–14.
5. Moscarelli M, Lorusso R, Angelinic G, Di Baria N, Paparella D, Fattouche K, et al. Sex-specific differences and postoperative outcomes of minimally invasive and sternotomy valve surgery. Euro J Cardiothorac Surg. (2022) 61:695–702.
6. Bakir I, Casselman F, Wellens F, Jeanmart H, De Geest R, Degrieck I, et al. Minimally invasive versus standard approach aortic valve replacement: a study in 506 patients. Ann Thorac Surg. (2006) 81:1599–604.
7. Tam R, Almeida A. Minimally invasive aortic valve replacement via partial sternotomy. Ann Thorac Surg. (1998) 65:275–6.